Liquid HandlingLiquid HandlingLab Automation Expertise
C-Series Syringe Pumps
BASE MODEL
C3000, C24000
FEATURES
The C-Series comprises syringe pump modules for automated instrumentation and can seamlessly replace XP, XCalibur, PSD/4 and PVM pumps. They provide low total cost of ownership as their proprietary, high efficiency direct drive system has no belts to stretch or snap – so it is maintenance-free. C-Series pumps also feature long-life rotary shear valves, which last up to 24x longer than competing valves. The valve drive achieves a performance of < 250ms between neighbouring ports. With C-Series pump modules, you can address up to 15 pumps individually and run in standard full-step mode or high-resolution mode up to 192,000 microsteps/fullstroke. The C24000 provides extremely low flowrates at minimum pulsation and sets new standards for syringe pumps in this application field.
· Fluid Contact Syringe Material
Borosilicate Glass and UHMWPE orPTFE (seal) – Pressures to 80 PSI
· Fluid Contact Valve Material
PCTFE or PEEK (housing) and PTFEor UHMWPE (plug) – Pressures to 100 PSI
· Accessories
Syringe Sizes: 50 μL, 100 μL, 250 μL, 500 μL,1 mL, 2.5 mL, 5 mL, 12.5 mL
Type: RS232, RS485 or CA
Communication Rates: RS232/RS485 9600 or 38400baud, CAN 100 K, 125 K, 250 K, 500 K, 1 M baudFormat (RS232/RS485): Data Bits - 8,Parity - None, Stop Bit - 1, Half Duplex,Data Terminal and OEM protocols
· Operating Conditions
Temperature 15°C to 40°C (59°F to 104°F)Humidity 20 to 95% RH at 40°C (104°F)
Multi-Channel Syringe Pump
BASE MODEL
MC6000-4, MC6000-6, MC6000-8
FEATURES
The MC6000 pump is the only one available on themarket with shear valves that eliminate the problemsassociated with solenoid valves. The valves are providedwith 1/4 –28 female ports and offer integrated bypasscapability. Absolute syringe positioning is verified witha full quadrature encoder whether running in standardmode (6,000 steps/full-stroke) or in high-resolutionmode (48,000 microsteps/full-stroke). The MC6000also includes front panel LEDs indicating flow andstatus, enabling you to easily monitor the process.The valve drive achieves a performance of < 250msbetween neighboring ports. With the MC6000, you canaddress up to 15 pumps individually.
OPTIONS
· Available
in 6 or 8 channel syringe configurations,4 channels on request
· Accessories
Syringe Sizes: 50 μL, 100 μL, 250 μL, 500 μL,Syringe Sizes: 50 μL, 100 μL, 250 μL, 500 μL,1 mL, 2.5 mL, 5 mL
· Interface
Type: USB, RS232, RS485 or CAN Communication Rates: RS232/RS485 9600 or 38400baud, CAN 100 K, 125 K, 250 K, 500 K, 1 M baudFormat (RS232/RS485): Data Bits - 8, Parity - None,Stop Bit - 1, Half Duplex, Data Terminal and OEM
· Operating Conditions
Temperature 15°C to 40°C (59°F to 104°F)Humidity 20 to 95% RH at 40°C (104°F)
LT-Series Pump
BASE MODEL
250 μL, 150 μL, 1.0 mL, 2.5 mL, 5.0 mL
FEATURES
Elegant in their simplicity, TriContinent LT SeriesElegant in their simplicity, TriContinent LT Seriessyringe pumps are renowned for their reliability andcost-effectiveness. With our advanced manufacturingprocesses we achieve near-perfect alignment of thesyringe, plunger seal and other drive elements resultingin long lifecycle with zero maintenance. This includesthe UHMWPE syringe seals, which combine resiliencewith exceptional longevity. With LT Series pumps, youbenefit from a wide range of options, including valves,electronics and encoders.
Drive Recommendations
Pump should typically be driven with a 24 VDC bipolar chopper drive, 1/2 step, at rated current. Higher voltage may be required at higher step rates.
Operating Conditions
Temperature (operating) 15°C to 45°C (59°F to 113°F) Humidity (operating) 10-85% RH (non-condensing)
OPTIONS
Available
in 250 μL, 500 μL, 1.0 mL, 2.5 mL, 5.0 mL
BasePump
BASE MODEL
BasePump
FEATURES
TriContinent’s range of BasePump syringe pumps are recognized throughout the industry for their quality, reliability and cost-effectiveness. You can choose from a wide range depending on your application needs – with or without valves and electronics. The BasePump range is also flexible, accommodating syringes of different sizes, from 50 μL to 10 mL.
- Driver Recommendation (min)
For Stepper Motor: Bipolar Chopper at 24 VDC, 350 mA per phase or equivalent
OPTIONS
- With or without Valve
- Accessories
Diluent Syringe Sizes – 500 μL, 2 mL, 5 mL, 10 mL Dual Port Sample Syringe Size – 50 μL, 250 μL Single Port Sample Syringe Size – 250 μL, 500 μL, 2 mL, 5 mL, 10 mL
AP2000
BASE MODEL
AP2000 for Diluent, AP2000 for Sample
FEATURES
Our AP2000 syringe pump is electronic and software compatible with the XE pump as it is economical
and flexible enough to be tailored to your needs. The AP2000 accommodates syringes with volumes ranging from 50 μL to 10 mL, and models are available with or without valves. It saves you money with low preventative maintenance costs and can address up to 15 pumps individually. Onboard electronics for computer control.
- Interface
Type: RS232, RS485 or CAN
Communication Rates: RS232/RS485 9600 or 38400
baud, CAN 100 K, 125 K, 250 K, 500 K, 1 M baud
Format (RS232/RS485): Data Bits - 8, Parity - None, Stop Bit - 1, Half Duplex, Data Terminal and OEM protocols
- Operating Conditions
Temperature 15°C to 40°C (59°F to 104°F) Humidity 20 to 95% RH at 40°C (104°F)
OPTIONS
- With or without Valve
- Accessories
Diluent Syringe Sizes – 500 μL, 2 mL, 5 mL, 10 mL Syringe Port Sample Syringe Sizes — 250 μL, 500 μL, 2 mL, 5 mL, 10 mL
Dual Port Sample Syringe Sizes — 50 uL, 250 uL
FOR MORE PRODUCTS CLICK THE ICON TO DOWNLOAD THE FULL PDF FILE